您好,欢迎来到保温材料网!
保温材料网

如何评定外保温系统的燃烧性能等级

来源:中国建筑科学研究院 2008-06-26 阅读:4199
  

[摘 要] 本文以《建筑材料及制品燃烧性能分级》(GB 8624-2006)为依据,首先对外墙外保温系统的构成及其组件进行了介绍,而后根据该标准的分级规定所涉及的试验方法和标准进行了综述,并对外墙外保温系统燃烧性能等级的评定进行了分析与探讨。
[关键词] 外墙外保温系统;试验方法;燃烧性能等级
[中图分类号] TU111.4+1;TU54   [文献标识码] A


How to Assess the Burning Behavior Class of External Thermal Insulation System
―Understanding “Classification for Burning Behavior of Building Materials and Products”(GB 8624C2006)
JI Guang-qi,ZHU Chun-ling (China Academy of Building Research,Beijing 100013,China)
[Abstract]In this paper, according to “Classification for Burning Behavior of Building Materials and Products”(GB 8624-2006), the composings of external thermal insulation systems were firstly introduced,and the test methods in this standard were secondly summarized. Lastly, the assessment of burning behavior class for external thermal insulation systems were analyzed and discussed.
[Keywords] external thermal insulation system, test method, burning behavior class

1 引 言

   《建筑材料及制品燃烧性能分级》(GB 8624-
2006)(以下简称《标准》)已于2007年3月1日起正式实施,尽管相关的设计、施工、验收等规范没有同步修订,给该标准的应用带来了一定的难度,但作为我国分级体系中的基础标准,将对建筑材料及其制品在建筑中的应用产生深远影响。 

   如何运用该《标准》评定建筑外墙外保温系统的燃烧性能等级,是大家所关心的问题。本文旨在认真学习领会《标准》的内涵,尝试对外墙外保温系统燃烧性能等级的评定进行分析和探讨。

2 外保温系统的组件

   根据《标准》的第1条,对建筑材料或制品的燃烧性能进行分级的基本原则是考虑建筑制品的最终应用形态,将其按类别划分。外保温系统属于非铺地材料建筑制品,应按非铺地材料的相关条文进行燃烧性能等级评定。

   根据《标准》中的分级基本原则,对于同一外保温系统,当某种材料的尺寸不同时,如保温层材料的厚度不同时,系统的燃烧性能等级可能不同,即应对具有不同尺寸的相同产品进行检验和燃烧性能等级的评定。

   运用《标准》对建筑外墙外保温系统的燃烧性能等级进行评定,首先要理解《标准》中的第3条术语和定义与外保温系统组件的对应关系。从广义上讲,外保温系统是由粘结层、保温层、抹面层和饰面层构成,按照术语和定义,整体上属于非匀质制品,且成分大多属于主要组分,只有界面剂和饰面涂层可能属于次要组分。

   1)当外保温系统中的界面剂尺寸或用量满足单层面密度小于1.0 kg/m2且单层厚度小于1.0 mm时,才可视作次要组分。

   2)当外保温系统的饰面涂层尺寸或用量满足单层面密度小于1.0 kg/m2且单层厚度小于1.0 mm时,才可视作外部次要组分。

   3)外保温系统组件中,主要组分和次要组分,内部组分和外部组分的界定,对于正确评定其燃烧性能等级是非常重要的。

新闻来源:中国建筑科学研究院

反对 0举报 0 收藏 0 打赏 0评论 0

免责声明:
本站部份内容系网友自发上传与转载,不代表本网赞同其观点;
如涉及内容、版权等问题,请在30日内联系,我们将在第一时间删除内容!